Size

Instrument : 8.3 cm width x 21.6 cm length x 5.6 cm depth ( 3.27 in x 8.5 in x 2.21 in )

4 port bulkhead with sensor guard, no depth : 42.82 cm ( 16.86 in ) length and 4.75 cm ( 1.87 in ) outer diameter

4 port bulkhead with sensor guard, with depth : 45.36 cm ( 17.86 in ) length and 4.75 cm ( 1.87 in ) outer diameter

ODO/CT assembly with sensor guard : 26.14 cm ( 10.29 in ) length and 2.46 cm ( 0.97 in ) outer diameter

Handheld weight with batteries

567 grams ( 1.25 lbs )

Power

Rechargeable lithium-ion battery pack provides ~48 hours with the handheld only and ~20 hours with the handheld, 4 port cable and 4 smart sensors; battery recharge time is ~9 hours with the AC power adapter

The instrument can also be powered via AC or external power pack through the USB port

Instrument operating temp.

0 to 50 °C ( 32 to 122 °F )

Instrument storage temp.

0 to 45 °C ( 32 to 113 °F ) with battery installed; 0 to 60 °C ( 32 to 140 °F ) without battery installed

Display

Color, LCD graphic display; 3.9 cm width x 6.5 cm height

USB port

Built-in micro USB On-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick

Cables

ProDSS 4 port, ProDSS ODO/CT, and ProODO field cables available in 1, 4, 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100-meters; ProDSS 4 port cables feature an optional depth sensor; ProOBOD cable assemblies are also compatible

Sensor ports

4 port cables feature universal sensor ports that can accept any ProDSS sensor; other compatible cables feature integral sensors

Warranty

3-year instrument; 2-year bulkhead, cable assembly, sensors, and extended warranty ODO sensor cap ( 627180 ); 1-year pH and pH/ORP sensor modules, ODO sensor caps, and Li-ion battery pack; 6-months ammonium, nitrate, and chloride sensor modules

Memory

> 100,000 data sets

Logging modes

Single point or continuous with autostable feature

GLP compliance

Yes; 400 detailed GLP records can be stored and are available to view, download, and print.

Languages

English,Spanish,German,French,Italian,Norwegian,Portuguese,Japanese,Chinese ( Simplified & Traditional ),Korean,Thai

Certifications

CEC, CE; RoHS; IP-67; WEEE; FCC; UN Part III, Section 38.3, Test methods for lithium-ion batteries ( Class 9 )

GPS

Optional internal GPS; coordinates are stored with measurement data and site lists

Sites and data ID

100 user-defined sites and 100 user-defined data ID tags; site pictures can be sent to the handheld via KorDSS

ProDSS System Specifications ( Instrument, Sensor, and Cable )

Sensor/Parameter

Range

Accuracy

Resolution

Units

Temperature

-5 to 70 °C ( E123 temp. Comp. range for DO mg/L measurement : -5 to 50 °C )

±0.2 °C

0.1 °C or 0.1 °F ( user selectable )

°C, °F, K

pH

0 to 14 pH units

±0.2 pH units

0.01 pH units

pH, pH mV

ORP

-1999 to 1999 mV

±20 mV

0.1 mV

mV

Dissolved Oxygen

0 to 500%, 0 to 50 mg/L

0 to 200 % : ±1 % of reading or 1 % saturation, whichever is greater

0.01 mg/L and 0.1 %, or 0.1 mg/L and 1 % ( user selectable )

% saturation, % saturation local, mg/L, ppm

200 to 500 % : ±8 % of reading

0 to 20 mg/L : ±0.1 mg/L or 1 % of reading, whichever is greater

20 to 50 mg/L : ±8 % of reading

Barometer

375 to 825 mmHg

±1.5 mmHg from 0 to 50 °C

0.1 mmHg

mmHg, inHg, mbar, psi, kPa, atm

Conductivity

0 to 200 mS/cm

0 - 100 mS/cm : ±0.5 % of reading or .001 mS/cm, whichever is greater

0.001, 0.01 or 0.1 µS/ cm ( range dependent )

μS/cm, mS/cm

100 - 200 mS/cm: ±1.0 % of reading

Specific Conductance*

0 to 200 mS/cm

0 - 100 mS/cm: ±0.5 % of reading or .001 mS/cm, whichever is greater

0.001, 0.01, 0.1 mS/cm

μS/cm or mS/cm

100 - 200 mS/cm: ±1.0 % of reading.

User selectable reference temperature ( 15 to 25 °C; default 25 °C ) and compensation coefficient ( 0 to 4 %/°C; default 1.91 % )

Salinity*

0 to 70 ppt

±1.0 % of reading or ±0.1 ppt, whichever is greater

0.01 ppt

ppt or PSU

TDS )*

0 to 100 g/L

Calculated from specific conductance and a user-selectable TDS

0.001, 0.01, 0.1 g/L

mg/L, g/L, kg/L

multiplier ( 0.30 to1.00;default 0.65 )

Resistivity*

0 to 2 Mohms

±0.1 % Full Scale

0.001, 0.01, 0.1 ohms

ohm-cm, kohm-cm, Mohm-cm

Seawater Density*

0.0 to 50.0 sigma, sigma T

-

0.1 sigma or sigma T

Sigma, Sigma T

Turbidity

0 to 4000 FNU

0 to 999 FNU: 0.3 FNU or ±2 % of reading, whichever is greater

0.1 FNU

FNU, NTU

1000 to 4000 FNU : ±5 % of reading

TSS )*

-

User correlated from turbidity field measurements and lab TSS measurements from grab samples

0.01, 0.1 mg/L

mg/L

Ammonium**

0 to 200 mg/L NH4-N

±10 % of reading or 2 mg/L, whichever is greater

0.01 mg/L

NH4-N mg/L, NH4-N mV

Ammonia*

0 to 200 mg/L NH3-N

-

0.01 mg/L

NH3-N mg/L

Chloride**

0 to 18000 mg/L Cl

±15 % of reading or 5 mg/L, whichever is greater

0.01 mg/L

Cl mg/L, Cl mV

Nitrate**

0 to 200 mg/L NO3-N

±10 % of reading or 2 mg/L, whichever is greater

0.01 mg/L

NO3-N mg/L, NO3-N mV

Depth

0 to 328 feet ( 0 to 100 m )

±0.013 ft ( ±0.004 m) for 1, 4, and 10 m cables

0.001 m or 0.01 ft

m, ft

±0.13 ft ( ±0.04 m ) for cables 20 m and longer

Alat Uji Kualitas Air