Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter HI98194

Specifications

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

pH Accuracy

±0.02 pH

pH Calibration

automatic one, two, or three points with automatic recognition of five standard buffers ( pH 4.01, 6.86, 7.01, 9.18, 10.01 ) or one custom buffer

mV Range

±600.0 mV

mV Resolution

0.1 mV

mV Accuracy

±0.5 mV

ORP Range

±2000.0 mV

ORP Resolution

0.1 mV

ORP Accuracy

±1.0 mV

ORP Calibration

automatic at one custom point ( relative mV )

EC Range

0 to 200 mS/cm ( absolute EC up to 400 mS/cm )

EC Resolution

auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging ( fixed mS/cm ): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01

EC Accuracy

±1% of reading or ±1 µS/cm whichever is greater

EC Calibration

automatic single point, with six standard solutions ( 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm ) or custom point

TDS Range

0 to 400000 ppm ( mg/L ); (the maximum value depends on the TDS factor)

TDS Resolution

manual : 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L ); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt):

TDS Accuracy

±1% of reading or ±1 ppm (mg/L), whichever is greater

TDS Calibration

based on conductivity or salinity calibration

Resistivity Range

0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm

Resistivity Resolution

dependent on resistivity reading

Resistivity Calibration

based on conductivity calibration

Salinity Range

0.00 to 70.00 PSU

Salinity Resolution

0.01 PSU

Salinity Accuracy

±2% of reading or ±0.01 PSU whichever is greater

Salinity Calibration

based on conductivity calibration

Seawater σ Range

0.0 to 50.0 σt, σ₀, σ₁₅

Seawater σ Resolution

0.1 σt, σ₀, σ₁₅

Seawater σ Accuracy

±1 σt, σ₀, σ₁₅

Seawater σ Calibration

based on conductivity or salinity calibration

DO Range

0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)

DO Resolution

0.1%; 0.01 ppm (mg/L)

DO Accuracy

0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading

DO Calibration

automatic one or two points at 0 and 100% or one custom point

Atmospheric Pressure Range

450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Atmospheric Pressure Resolution

0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Atmospheric Pressure Accuracy

±3 mm Hg within ±15°C from the temperature during calibration

Atmospheric Pressure Calibration

automatic at one custom point

Temperature Range

-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K

Temperature Resolution

0.01 K, 0.01 °C, 0.01 °F

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Calibration

automatic at one custom point

Temperature Compensation

automatic from -5 to 55 °C (23 to 131 °F)

Logging Memory

45,000 records (continuous logging or log-on-demand of all parameters)

Logging Interval

one second to three hours

PC Connectivity

USB to PC with HI9298194 Hanna software installed

Battery Type/Life

1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)

Environment

0 to 50°C (32 to 122°F); RH 100% (IP67)

Dimensions

185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)

Weight

400 g (14.2 oz.)

Ordering Information

HI98194 is supplied with HI7698194 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.

Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with optional GPS HI9829

Specifications

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

pH Accuracy

±0.02 pH

pH Calibration

automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer

mV Range

±600.0 mV

mV Resolution

0.1 mV

mV Accuracy

±0.5 mV

ORP Range

±2000 mV

ORP Resolution

0.1 mV

ORP Accuracy

±1.0 mV

ORP Calibration

automatic at one custom point (relative mV)

EC Range

0 to 200 mS/cm (absolute EC up to 400 mS/cm)

EC Resolution

Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm

EC Accuracy

±1% of reading or ±1 µS/cm whichever is greater

EC Calibration

automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point

TDS Range

0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)

TDS Resolution

Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)

TDS Accuracy

±1% of reading or ±1 ppm (mg/L), whichever is greater

TDS Calibration

based on conductivity or salinity calibration

Resistivity Range

0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm

Resistivity Resolution

dependent on resistivity reading

Resistivity Calibration

based on conductivity calibration

Salinity Range

0.00 to 70.00 PSU

Salinity Resolution

0.01 PSU

Salinity Accuracy

±2% of reading or ±0.01 PSU whichever is greater

Salinity Calibration

based on conductivity calibration

Seawater σ Range

0.0 to 50.0 σt, σ₀, σ₁₅

Seawater σ Resolution

0.1 σt, σ₀, σ₁₅

Seawater σ Accuracy

±1 σt, σ₀, σ₁₅

Seawater σ Calibration

based on conductivity or salinity calibration

Ammonium-Nitrogen Range

0.02 to 200.0 ppm Am (as NH4 +-N)

Ammonium-Nitrogen Resolution

0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm

Ammonium-Nitrogen Accuracy

±5 % reading or 2 ppm

Ammonium-Nitrogen Calibration

1 or 2 point, 10 ppm and 100 ppm

Chloride Range

0.6 to 200.0 ppm Cl (as Cl- )

Chloride Resolution

0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm

Chloride Accuracy

±5 % of reading or 2 ppm

Chloride Calibration

1 or 2 point, 10 ppm and 100 ppm

Nitrate-Nitrogen Range

0.62 to 200.0 ppm Ni (as NO3 - -N)

Nitrate-Nitrogen Resolution

0.01 ppm to 1 ppm 0.1 ppm to 200 ppm

Nitrate-Nitrogen Accuracy

±5 % of reading or 2 ppm

Nitrate-Nitrogen Calibration

1 or 2 point, 10 ppm and 100 ppm

Turbidity Range

0.0 to 99.9 FNU; 100 to 1000 FNU

Turbidity Resolution

0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU

Turbidity Accuracy

±0.3 FNU or ±2 % of reading, whichever is greater

Turbidity Calibration

Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom

DO Range

0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)

DO Resolution

0.1%; 0.01 ppm (mg/L)

DO Accuracy

0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading

DO Calibration

automatic one or two points at 0 and 100% or one custom point

Atmospheric Pressure Range

450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Atmospheric Pressure Resolution

0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Atmospheric Pressure Accuracy

±3 mm Hg within ±15°C from the temperature during calibration

Atmospheric Pressure Calibration

automatic at one custom point

Temperature Range

-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K

Temperature Resolution

0.01 K, 0.01 °C, 0.01 °F

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Calibration

automatic at one custom point

Temperature Compensation

automatic from -5 to 55 °C (23 to 131 °F)

Logging Memory

44,000 records (continuous logging or log-on-demand of all parameters)

Logging Interval

one second to three hours

PC Connectivity

USB (with HI 929829 software)

Battery Type/Life

1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration

Waterproof Protection

IP67

Environment

0 to 50°C (32 to 122°F); RH max 100%

Dimensions

221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)

Weight

750 g (26.5 oz.)

GPS

12 channel receiver 10 m (30 ft) accuracy

Ordering Information

The HI9829 and HI98290 (GPS model) are supplied with a HI710140 hard carrying case, HI7612VDC adapter, HI7698292 probe maintenance kit, HI929829 PC application software, HI7698291 USB cable (PC to meter), HI710045 power supply cable, HI710046 cigarette lighter power cable, HI9828-25 quick calibration solution, HI920005 iButton with holder (5), HI7609829-1 pH/ORP sensor, HI7609829-2 galvanic DO sensor, HI7609829-3 EC sensor, HI7698290 short calibration beaker, HI7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual.

Probes selected with turbidity option will include the HI7609829-4 EC/turbidity sensor, HI7698293 long calibration beaker and HI7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI9829-16 0 FNU, HI769829-17 20 FNU, and HI9829-18 200 FNU.

Multiparameter pH/ORP/DO/Pressure/Temperature Waterproof Meter HI98196

Specifications

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

pH Accuracy

±0.02 pH

pH Calibration

automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer

mV Range

±600.0 mV

mV Resolution

0.1 mV

mV Accuracy

±0.5 mV

ORP Range

±2000 mV

ORP Resolution

0.1 mV

ORP Accuracy

±1.0 mV

ORP Calibration

automatic at one custom point (relative mV)

DO Range

0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)

DO Resolution

0.1%; 0.01 ppm (mg/L)

DO Accuracy

0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading

DO Calibration

automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L).

Atmospheric Pressure Range

450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Atmospheric Pressure Resolution

0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Atmospheric Pressure Accuracy

±3 mm Hg within ±15°C from the temperature during calibration

Atmospheric Pressure Calibration

automatic at one custom point

Temperature Range

-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K

Temperature Resolution

0.01 K, 0.01 °C, 0.01 °F

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Calibration

automatic at one custom point

Temperature Compensation

automatic from -5 to 55 °C (23 to 131 °F)

Logging Memory

45,000 records (continuous logging or log-on-demand of all parameters)

Logging Interval

one second to three hours

PC Connectivity

USB to PC with HI9298194 Hanna software installed

Battery Type/Life

1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)

Environment

0 to 50°C (32 to 122°F); RH 100% (IP67)

Dimensions

185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)

Weight

400 g (14.2 oz.)

Ordering Information

HI98196 is supplied with HI7698196 probe, HI7698194-1 pH/ORP sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.

Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter HI98196

Specifications

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

pH Accuracy

±0.02 pH

pH Calibration

automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer

mV Range

±600.0 mV

mV Resolution

0.1 mV

mV Accuracy

±0.5 mV

ORP Range

±2000.0 mV

ORP Resolution

0.1 mV

ORP Accuracy

±1.0 mV

ORP Calibration

automatic at one custom point (relative mV)

EC Range

0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm)

EC Resolution

auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01

EC Accuracy

±1% of reading or ±1 µS/cm whichever is greater

EC Calibration

automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point

TDS Range

0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor)

TDS Resolution

manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt):

TDS Accuracy

±1% of reading or ±1 ppm (mg/L), whichever is greater

TDS Calibration

based on conductivity calibration

Resistivity Range

0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm

Resistivity Resolution

dependent on resistivity reading

Resistivity Calibration

based on conductivity calibration

Salinity Range

0.00 to 70.00 PSU

Salinity Resolution

0.01 PSU

Salinity Accuracy

±2% of reading or ±0.01 PSU whichever is greater

Salinity Calibration

based on conductivity calibration

Seawater σ Range

0.0 to 50.0 σt, σ₀, σ₁₅

Seawater σ Resolution

0.1 σt, σ₀, σ₁₅

Seawater σ Accuracy

±1 σt, σ₀, σ₁₅

Seawater σ Calibration

based on conductivity calibration

Atmospheric Pressure Range

450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Atmospheric Pressure Resolution

0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Atmospheric Pressure Accuracy

±3 mm Hg within ±15°C from the temperature during calibration

Atmospheric Pressure Calibration

automatic at one custom point

Temperature Range

-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K

Temperature Resolution

0.01 K, 0.01 °C, 0.01 °F

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Calibration

automatic at one custom point

Temperature Compensation

automatic from -5 to 55 °C (23 to 131 °F)

Logging Memory

45,000 records (continuous logging or log-on-demand of all parameters)

Logging Interval

one second to three hours

PC Connectivity

USB to PC with HI9298194 Hanna software installed

Battery Type/Life

1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)

Environment

0 to 50°C (32 to 122°F); RH 100% (IP67)

Dimensions

185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)

Weight

400 g (14.2 oz.)

Ordering Information

HI98195 is supplied with HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI 76981952 Probe maintenance kit (O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.