close
menu

PSC

sql
Evolution 260 Bio Spectrophotometer Thermo Scientific
Evolution 260 Bio Spectrophotometer Thermo Scientific
Evolution 260 Bio Spectrophotometer Thermo Scientific
Evolution 260 Bio Spectrophotometer Thermo Scientific
Hover to Zoom

Jual Evolution 260 Bio Spectrophotometer Thermo Scientific



Spesifikasi Evolution 260 Bio Spectrophotometer Thermo Scientific

Evolution 260 Bio Spectrophotometer plus Tablet Control Module

Full specifications

Accuracy ( Photometric ) 1A : ±0.006A

2A : ±0.010A

Measured at 440 nm using calibrated neutral density filters traceable to NIST

Baseline Flatness ±0.0010A, 200-800 nm, 1.0 nm SBW, smoothing

Beam Geometry Double-beam with Application Focused Beam Geometry

Certifications/Compliance ISO 9001:2008

Data Interval 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm

Description Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International

Detector Type Dual Silicon Photodiodes

Dimensions ( L x W x H ) 62.2 x 48.6 x 27.9 cm

Display Touchscreen LCD panel; 800 x 480; 17.8 cm ( 7 in. Diagonal )

Drift <0.0005 A/hr, 500 nm, 1.0 nm SBW, 1 hr warm-up

Electrical Requirements 100-240 V 50-60 Hz selected automatically 150 W maximum

Item Description Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International

Keypad Sealed membrane

Lamp Xenon Flash Lamp, 3-year warranty ( 7 years typical lifetime )

Noise 0A : <0.00015A

1A : <0.00025A

2A : <0.00080A

260 nm, 1.0 nm SBW, RMS

Operating System Microsoft Windows™ XP embedded 

INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument

Optical Design Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator

Pharmacopoeia Compliance Testing ( Guaranteed Performance Specifications )

Resolution ( toluene in Hexane ) : ≥1.8A

Photometric Accuracy ( 60 mg/L K2Cr2O7 ) : ±0.010A

Stray Light : ≤1 %T at 198 nm : KCI; ≤0.05 % AT at 220 nm : Nal, KI

Wavelength Accuracy : ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range

Wavelength Repeatability : ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line

Photometric Accuracy Instrument 1A : ±0.006A

2A : ±0.010A

Measured at 440 nm using calibrated neutral density filters traceable to NIST

Photometric Display -0.3 - 4.0A

Photometric Range >3.5A

Photometric Repeatability ±0.0002A

Scan Ordinate Modes Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log ( 1/R ), log ( Abs ), Abs*Factor, Intensity

Scan Speed <1-6000nm/min, variable

Spectral Bandwidth Variable : 1.0 nm; 2.0 nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized

Type Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International

Wavelength Accuracy ±0.5 nm ( 541.9, 546.1 nm mercury lines )

±0.8 nm ( full range 190-1100 nm )

Wavelength Range 190 - 1,100 nm

Wavelength Scan Speed <1 to 6,000 nm/min; variable

Weight ( Metric ) 14.4 kg

Catalog Number 912A0888

 

Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes power cords

Full specifications

Accuracy ( Photometric ) 1A : ±0.006A

2A : ±0.010A

Measured at 440 nm using calibrated neutral density filters traceable to NIST

Baseline Flatness ±0.0010A, 200-800 nm, 1.0 nm SBW, smoothing

Beam Geometry Double-beam with Application Focused Beam Geometry

Certifications/Compliance ISO 9001:2008

Data Interval 10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm

Description Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords

Detector Type Dual Silicon Photodiodes

Dimensions ( L x W x H ) 62.2 x 48.6 x 27.9 cm ( 24 x 19 x 11 in )

Drift <0.0005 A/hr, 500 nm, 1.0 nm SBW, 1 hr warm-up

Electrical Requirements 100-240 V 50-60 Hz selected automatically 150 W maximum

Lamp Xenon Flash Lamp, 3-year warranty ( 7 years typical lifetime )

Noise 0A : <0.00015A

1A : <0.00025A

2A : <0.00080A

260 nm, 1.0 nm SBW, RMS

Operating System Microsoft Windows 7, Windows 8

Optical Design Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator

Pharmacopoeia Compliance Testing ( Guaranteed Performance Specifications )

Resolution ( toluene in Hexane ) : ≥1.8A

Photometric Accuracy ( 60 mg/L K2Cr2O7 ) : ±0.010A

Stray Light : ≤1 %AT at 198 nm: KCI; ≤0.05 %AT at 220 nm : Nal, KI

Wavelength Accuracy : ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range

Wavelength Repeatability : ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line

Photometric Accuracy Instrument 1A : ±0.006A

2A : ±0.010A

Measured at 440 nm using calibrated neutral density filters traceable to NIST

Photometric Display -0.3 - 4.0A

Photometric Range >3.5A

Photometric Repeatability ±0.0002A

Scan Ordinate Modes Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log ( 1/R ), log ( Abs ), Abs*Factor, Intensity

Scan Speed <1-6000 nm/min, variable

Spectral Bandwidth Variable : 1.0 nm; 2.0 nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized

Type Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords

Wavelength Accuracy ±0.5 nm ( 541.9, 546.1 nm mercury lines )

±0.8 nm ( full range 190-1100 nm )

Wavelength Range 190 to 1100 nm

Wavelength Scan Speed <1 to 6000 nm/min; variable

Weight ( English ) 32 lb

Weight ( Metric ) 14.4 kg

Catalog Number 840-211000