phone Phone
+622122685913
close
menu

PSC

sql
Ammonia Cheqker Hanna Instruments
Ammonia Cheqker Hanna Instruments
Ammonia Cheqker Hanna Instruments
Ammonia Cheqker Hanna Instruments
Ammonia Cheqker Hanna Instruments
Ammonia Cheqker Hanna Instruments
Hover to Zoom

Jual Ammonia Cheqker Hanna Instruments



Spesifikasi Ammonia Cheqker Hanna Instruments

Ammonia Cheqker Hanna Instruments

Ammonia Low Range Checker® HC - HI700

Specifications

Range

0.00 to 3.00 ppm NH3-N

Resolution

0.01

Accuracy @ 25°C

±0.05 ppm ±5 % of reading

Light source

LED @ 470 nm

Light Detector

Silicon photocell

Method

Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

Environment

0 to 50°C; RH max 95% non-condensing

Battery Type

( 1 ) 1.5V AAA

Auto-off

After ten minutes of non-use

Dimensions

81.5 mm x 61 mm x 37.5 mm

Weight

64 g

Ordering Information

HI-700 Checker® is supplied with ( 2 ) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI-700A-0 reagent A and 1 bottle of HI-700B-0 reagents B), battery, instructions.

Ammonia Medium Range Checker® HC - HI715

Specifications

Range

0.00 to 9.99 ppm NH₃-N

Resolution

0.01 ppm

Accuracy @ 25°C/77°F

±0.05 ppm ±5% of reading

Light Source

LED @ 470 nm

Light Detector

silicon photocell

Method

adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

Environment

0 to 50°C ( 32 to 122°F ); RH max 95% non-condensing

Battery Type

( 1 ) 1.5V AAA

Auto-off

after ten minutes of non-use

Dimensions

81.5 mm x 61 mm x 37.5 mm ( 3.2" x 2.4" x 1.5” )

Weight

64 g ( 2.25 oz .)

Ordering Information

HI715 Checker® is supplied with ( 2 ) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI715A-0 and 1 bottle of HI715B-0), ­­­battery, instructions and quick start guide.

Ammonia High Range Checker® HC - HI733

Specifications

Range

0.0 to 99.9 ppm as NH₄⁺

Resolution

0.1 ppm

Accuracy @ 25°C/77°F

±1.0 ppm ±5 % of reading

Light Source

LED @ 470 nm

Light Detector

silicon photocell

Method

adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

Environment

0 to 50°C ( 32 to 122°F ); RH max 95% non-condensing

Battery Type

( 1 ) 1.5V AAA

Auto-off

after ten minutes of non-use

Dimensions

81.5 mm x 61 mm x 37.5 mm ( 3.2" x 2.4" x 1.5” )

Weight

64 g ( 2.25 oz. )

Ordering Information

HI733 Checker® is supplied with ( 2 ) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI733A-0 and 1 bottle of HI733B-0 ), battery, instructions and quick start guide

Alat Uji Kualitas Air

Untuk keterangan lebih lanjut, silahkan download PDF ini :