SPECIFICATIONS

Sensor Type 90° light scattering

Particle Size Range 0.1 to 10 µm

Aerosol Concentration Range

  • 8530 Desktop 0.001 to 400 mg/m3
  • 8530EP Desktop with External Pump 0.001 to 400 mg/m3
  • 8532 Handheld 0.001 to 150 mg/m3

Resolution ±0.1 % of reading or 0.001 mg/m3, whic hever is greater

Zero Stability ±0.002 mg/m3 per 24 hours at 10 sec time constant

Flow Rate 3.0 L/min set at factory, 1.40 to 3.0 L/min, user adjustable

Flow Accuracy ±5 % of factory set point, internal flow controlled

Temperature Coefficient +0.001 mg/m3 per °C

Operational Temp 32 to 120 °F ( 0 to 50 °C )

Storage Temp -4 to 140 °F ( -20 to 60 °C )

Operational Humidity 0 to 95 % RH, non-condensing

Time Constant User adjustable, 1 to 60 seconds

Data Logging 5 MB of on-board memory ( >60,000 data points )

45 days at 1 minute logging interval

Log Interval User adjustable, 1 second to 1 hour

Physical Size ( H x W x D )

Handheld   4.9 x 4.8 x 12.5 in.

( 12.5 x 12.1 x 31.6 cm )

Desktop     5.3 x 8.5 x 8.8 in.

External Pump  4.0 x 7.0 x 3.5 in.

( 10.0 x 18.0 x 9.0 cm )

Weight

Handheld   2.9 lb ( 1.3 kg ), 3.3 lb ( 1.5 kg ) with battery

Desktop     3.5 lb ( 1.6 kg ), 4.5 lb ( 2.0 kg )–1 battery, 5.5 lb ( 2.5 kg )–2 batteries

External Pump  3.0 lb ( 1.4 kg )

Communications

  • 8530 USB

( host and device ) and Ethernet. Stored data accessible using flash memory drive

  • 8530EP USB

( host and device ) and Ethernet. Stored data accessible using flash memory drive plus, cable assembly for external pump

  • 8532 USB

( Hose and device ). Stored data accessible using flash memory drive

Power–AC Switching AC power adapter with universal line cord included, 115–240 VAC 

Analog Out

  • 8530/8530EP

User selectable output,

0 to 5 V or 4 to 20 mA.

User selectable scaling range

Alarm Out

  • 8530/8530EP

Relay or audible buzzer

Relay

Non-latching MOSFET switch

+ User selectable set point

+ –5 % deadband

+ Connector 4-pin,

Mini-DIN connectors

  • 8532

Audible buzzer

Screen

  • 8530 5.7 in. VGA color touchscreen
  • 8532 3.5 in. VGA color touchscreen

Gravimetric Sampling

  • 8530/8530EP Removable 37 mm cartridge ( user supplied )

CE Rating Immunity

  • EN61236-1:2006
  • Emissions EN61236-1:2006


Order Information

Models Description


8530 Includes Carrying case, Rechargeable 7800 mAH Li-Ion Battery, Switching Power Supply with Universal plugs, TrakPro Data Analysis Software CD, zero filter, USB ( device and host ) computer cables, analog/alarm output connector, inlet cap ( 2 ), 37-mm cassette with mesh filter, 10-mm nylon Door-Oliver Cyclone, impactor kit ( with PM1, PM2.5, PM4, PM10 impactors ), impactor plates ( 2 ) and impactor oil ( 5 ml ), sample extension tube ( 3-ft/1-m ), sheath air HEPA filters ( 4 ), filter removal tool, operation <( >&< )> service manual, calibration certificate and 2-year warranty.


8532 Includes Carrying case, Rechargeable 3600 mAH Li-Ion Battery, Switching Power Supply with Universal plugs, TrakPro Data Analysis Software CD, zero filter, USB ( device and host ) computer cables, inlet cap ( 2 ), 10-mm nylon Dorr-Oliver Cyclone, impactor kit ( with PM1, PM2.5, PM4, PM10 impactors, impactor plates ( 2 ), and impactor oil ( 5 ml ), sample extension tube ( 3-ft/1-m ), sheath air HEPA filters ( 8 ), filter removal tool, screwdriver, operation & service manual, calibration certificate and 2-year warranty.


8533 Includes Carrying case, Rechargeable 7800 mAH Li-Ion Battery, Switching Power Supply with Universal Plugs, TrakPro Data Analysis Software CD, zero filter, USB ( device and host ) computer cables, analog/alarm output connector, inlet cap ( 2 ), 37-mm cassette with mesh filter, calibration impactor kit (with PM2.5 impactor, impactor plates ( 2 ) and impactor oil ), sample extension tube ( 3-ft/1-m ), sheath air HEPA filters ( 4 ), filter removal tool, operation & service manual, calibration certificate and 2-year warranty.


8534 Includes Carrying case, Rechargeable 3600 mAH Li-Ion Battery, Switching Power Supply with Universal Plugs, TrakPro Data Analysis Software CD, zero filter, USB ( device and host ) computer cables, inlet cap ( 2 ), calibration impactor kit ( with PM2.5 impactor, impactor plates ( 2 ), and impactor oil ), screwdriver, sample extension tube ( 3-ft/1-m ), sheath air HEPA filters ( 8 ), filter removal tool, operation & service manual, calibration certificate and 2-year warranty.


DustTrak II and DRX Accessories


800663 Zero filter. Qty 1.

801666 Internal Filter Kit, DustTrak II and DRX Handheld Models; 8 filters per package.

801667 Impactor kit, DustTrak II ( only ) Models 8530/8531/8532. Includes: PM1, PM2.5, PM4, PM10 Impactor Inlets, Impactor Bottom, Impaction Plates ( Qty 2 ), Impactor Oil ( 5 ml ).

801668 Filter Removal Tool, Models 853X ( ALL MODELS )

801669 Case, DustTrak II and DRX Handheld Models 8532/8534

801670 Case, DustTrak II and DRX Desktop Models 8530/8531/8533

801671 Standard Calibration Kit for DustTrak DRX Models 8533/8534. Includes PM2.5 Impactor, Impactor Plate ( Qty 2 ), Impactor Oil ( 5 mn ).

801685 External Battery Charger for 6600 or 7800 mAh batteries ( both 801680 ) used in Desktop Models 8530/8533. Batteries NOT included.

801681 Battery, 3600 mAH Li-Ion, for Handheld DustTrak 8532, 8534.

801680 Battery, 7800 mAH Li-Ion for DeskTop Models 8530, 8530EP, 8533, 8533EP.

801674 Impactor Oil for DustTrak II/DRX/AM520/AM520i; 5 ml bottle.

801673 Internal Filter Kit/37 mm Replacement Filter, DustTrak II and DRX Desktop Models 8530/8531/8533

801686 External Battery Charger for 3600 mAh battery ( 801681 ) used in Handheld models 8532/8534. Batteries NOT included.

801690 Autozero Module, DustTrak II and DRX

801691 10 mm nylon Dorr-Oliver Cyclone with cyclone clip and tubing

801692 AC Adaptor / Power Supply to power the instrument and charge batteries inside the instrument. Use for DustTrak II/DRX Desktop Models 8530/8531/8532, OPS Model 3330, and AeroTrak Desktop OPCs.

801694 AC Adapter / Power Supply to power instrument and charge batteries inside the instrument. Use for DustTrak II/DRX Handheld Models 8532/8534, and AeroTrak 9306V OPCs.

801652 Analog / alarm output connector

801698 Inlet Cap ( x2 ), DustTrak II and DRX Models 853x ( all models )

801688 Tubing, Conductive ( 3ft-1 m ) DustTrak II and DRX Models 853x ( all models )

801687 Hard sided, wheeled carry case for DustTrak II/DRX and PortaCount Pro/Pro+

1303740 Cable, Computer, USB, 6-ft/1.8-meter, USB-A Male to USB-B Male

801675 DustTrak II/DRX Complete Replacement External Pump Kit. Fully assembled external pump module, ready for connecton to DustTrak EP Model.

801795 DustTrak II/DRX External Pump Service Kit, includes: ( x2 ) HEPA Filters; ( x2 ) O-rings for Colder Connectors; and ( x1 ) O-ring for Exhaust Adapter.

801797 External Pump Power Cable ( to DustTrak )

801798 External Pump Flow Tube ( to DustTrak )

801799 DustTrak External Pump Replacement Kit. Includes: replacement pump and instructions for installing the new pump inside the External Pump module.

801907 Wireless Router Mounting Hardware for DustTrak

801903 Wireless Router, USB Cable and 1dB Antenna for Environmental DustTrak and DustTrak Aerosol Monitors

Air Quality Meter